ASA 5510 Integrated Digital and Analog Signal Analyzer is an all-in-one CATV signal analyzer/tester providing today’s engineers a complete portable tool in resolving digital video broadcast, transport, or reception challenges. The 5510 Series is capable of testing and analysing optical or RF CATV signals, DVB-C HD/SD digital broadcast channels with integrated TV video monitor and audio amplifier.
• Compact all-in-one CATV signal analyzer/tester
• Display measured values and TV images at the same time
• Support analog TV signal parameter measurement
• Support DVB-C digital signal features: average peak power, MER, BER, C/N, EVM, constellation diagram
• Built-in audio amplifiers, left and right channels
• Built-in lithium battery
• Conditional Access Verimatrix Smart card Slot
• Support both at channel and frequency mode
• Scan all channels and store signal level
• Carry out spectrum display and test for a certain frequency range
• Can measure CATV TILT, C/N, trunk cable Voltage, etc.
• Can measure DVB-C digital signal features: average peak power, MER, BER, C/N, EVM, constellation diagram
• LCD displays all testing results as well as CATV images
• Water proof travelling casing design
ASA 5510 Integrated Digital and Analog Signal Analyser Kit
Frequency | |
Frequency Range | 5 MHz to 1000 MHz |
Frequency Accuracy | ± 50 ppm (@ 20°C ±5°C) |
Frequency Resolution | 10kHz |
Channel Type | |
Analog TV | PAL/ NTSC |
Digital TV | QAM 16/32/64/128/256 with constellation diagram plus QPSK and COFDM |
FM Radio | Single frequency |
Digital Channel | |
Demodulation Type | Standard ITU‑T J.83 Annex A/B/C |
Support | QAM 16/32/64/128/256 |
Symbol Rate | 1 MS/sec to 7 MS/sec |
Bandwidth | 280 kHz to 10 MHz |
MER (Modulation Error Ratio) | 39 dB (QAM) |
Accuracy | ±2.0 dB |
BER (Bit Error Rate) | 1E‑3 to 1E‑8 before and after R‑S decoding (QAM) |
Power Measurement Type | QAM, QPSK and COFDM |
Digital Channel Average Power | |
Level Range | ‑30 dBmV to +60 dBmV |
Constellation | |
Accuracy | ±2.0 dB from 10°C to 30°C and ±3.0 dB from ‑10°C to 40°C |
Resolution | 0.1 dB |
Display Mode | QAM 64 and QAM 256 with zoom in and zoom out capability |
Analog Level Measurement | |
Range | ‑35 dBmV to +60 dBmV |
Accuracy | ±1.5 dB |
Resolution | 0.1 dB |
Input Impedance | 75Ω (“F” type connector) |
HUM Modulation | |
Range | 2% to 5% |
Channel Scan | |
Number of Channels | 160 channels max |
Scanning Speed | 5 channels per second |
Scale | 1, 2, 5, 10 dB/div |
Zoom | 1X, 2X, 3X, 4X, 5X five levels of magnification or full channel scan |
Frequency Spectrum | |
Bandwidth | 2.5MHz, 6.25 MHz, 12.5 MHz, 25 MHz, 62.5 MHz and full span |
Scale | 1 dB, 2 dB, 5 dB and 10 dB/div |
Tilt Measurement | |
Number of Frequencies | maximum 12 with 0.1 dB of resolution |
Limit Test Parameters | |
Min/Max Video Level | 0 dBmV to + 30 dBmV |
Min/Max Δ V/A | 10 dB to 20 dB |
Min/Max Power Level | 10 dBmV to +30 dBmV |
Minimum MER | 33 dB (varies with modulations and systems) |
Max PRE/POST BER | 1.0 Eˉ9 |
Auto‑Test | |
Number of Programs | Maximum 7 test parameters |
Line Voltage Measurement | |
Range | 0 V to 100 V (AC/DC) with accuracy of ±2 V |
RF Signal Optical Input Measurement | |
Wavelength | 1200 to 1600nm |
Optical Input Power | ‑14 to +3dBm (AGC: ‑8 to 0dBm) |
Optical Return Loss | ‑55dB |
Output Level | 80dBuV@(‑8 to 0dBm) |
RF Flatness | ±1dB |
RF Return Loss | ≥14dB |
Carrier/Noise | |
Level Range: | 80dBμV to 105dBμV |
Storage | |
Memory | 512K byte |
Accessories | |
Battery Charger | Battery charger |
RF Input/Output Port | F Type (2) |
Optical Attenuator | 2 |
RF Jumper | 1 |
RF Connector | 2 |
Environment | |
Dimension | 415 mm × 320 mm × 170 mm |
Weight | 7.2 kg |
Working Temperature: | ‑10 °C to +40 °C |