The DFPP-LP-CXX-10 is a high-performance 10G CWDM SFP+ transceiver engineered for optical data transmission and reception over single-mode fiber links up to 10 kilometers. Designed for demanding 10GBASE-LR applications, this module features a CWDM DFB laser and complies with SFI electrical specifications, ensuring robust signal integrity and minimal EMI through differential AC coupling and high-quality termination. The transceiver's transmitter section converts high-speed electrical data into optical signals, featuring an internal Automatic Power Control (APC) loop that maintains consistent optical output despite voltage or temperature changes. It includes important safety and diagnostic functions, such as TX_Disable and TX_Fault indicators, providing system-level control and real-time fault detection. These functions help ensure reliable operation and simplify integration into network equipment. On the receiving end, the module transforms incoming 10Gbps optical signals into PECL/CML electrical outputs, with a built-in Loss of Signal (Rx_LOS) feature that alerts the host system to degraded or absent signal conditions. This makes the DFPP-LP-CXX-10 ideal for ensuring high data integrity in long-reach optical links, helping identify issues such as disconnected cables or non-functioning transmitters. Overall, it offers a compact and efficient solution for CWDM optical networking with a strong emphasis on stability, reliability, and compliance with industry standards.
· 10Gb/s serial optical interface compliant to 802.3ae 10GBASE-LR
· Electrical interface compliant to SFF-8431
· Small Form Factor Pluggable compliant to SFF-8432
· LC Duplex connector
· CWDM DFB transmitter, PIN photo-detector
· 2-wire interface for management specifications compliant with SFF 8472 digital diagnostic monitoring interface for optical transceivers
· Low EMI
· Low power consumption
· Advanced firmware allow customer system encryption information to be stored in transceiver
· Cost effective SFP+ solution, enables higher port densities and greater bandwidth
· RoHS compliant
· Operating case temperature range:
Commercial: 0 to 70 °C
Industrial: -40 to 85 °C
Recommended Operating Conditions
Recommended Operating Environment specifies parameters for which the electrical and optical characteristics hold unless otherwise noted.
Parameter | Symbol | Min. | Typ. | Max. | Unit | Note |
Power Supply Voltage | Vcc | 3.135 | 3.3 | 3.465 | V | |
Power Supply Current | Icc | 350 | mA | |||
Operating Case Temperature | TC | 0 | 25 | 70 | °C | |
Relative Humidity | RH | 5 | 95 | % |
Optical Characteristics
Parameter | Values | Unit |
Operating Reach | 10 | km |
Transmitter | ||
Center Wavelength (Range) | 1391, 1411, 1431, 1451, 1471, 1491, 1511, 1531, 1551, 1571, 1591, 1611 | nm |
Side Mode Suppression Ratio (Min) | 30 | dB |
Output Power | 0 to 6 | dBm |
Average Launch Power | 0 to 6 | dBm |
Transmitter and Dispersion Penalty (Max) | 3.2 | dB |
Average Launch Power of OFF Transmitter (Max) | -30 | dBm |
Extinction Ratio (Min) | 3.5 | dB |
RIN12 OMA (Max) | -128 | dB/Hz |
Optical Return Loss Tolerance (min) | 12 | dB |
Receiver | ||
Center Wavelength (Range) | 1391, 1411, 1431, 1451, 1471, 1491, 1511, 1531, 1551, 1571, 1591, 1611 | nm |
Receive Overload (Max) in Average Power (Note 1) | 0.5 | dBm |
Receive Sensitivity (Min) in Average Power (Note 2) | -14.4 | dBm |
Receiver Reflectance (Max) | -12 | dB |
Los Assert (Min) | -30 | dBm |
Los Dessert (Max) | -15 | dBm |
Los Hysteresis(min) | 0.5 | dB |
Receive Electrical 3dB Upper Cutoff Frequency (Max) | 12.3 | dBm |
Receiver Power (Damage, Max) | +7 | dBm |
Notes:
1. Average optical power shall be measured using the methods specified in TIA/EIA-455-95.
2. Measured with a PRBS 2^31-1 test pattern, @ 10.325 Gb/s, BER≤10^-12.
3. Path penalty is intended as the power penalty of the interface between back-to-back and the maximum applied dispersion.
Electrical Characteristics
The following electrical characteristics are defined over the Recommended Operating Environment unless otherwise specified.
Parameter | Symbol | Min. | Typ. | Max. | Unit | Note |
Data Rate | 9.95 | 10.3125 | 11.3 | Gbps | ||
Power Consumption | 1.5 | mW | ||||
Transmitter | ||||||
Single Ended Output Voltage Tolerance | -0.3 | 4 | V | |||
C common Mode Voltage Tolerance | 15 | mV | ||||
Tx Input Diff Voltage | VI | 180 | 800 | mV | ||
Tx Fault | VoL | -0.3 | 0.4 | V | At 0.7mA | |
Data Dependent Input Jitter | DDJ | 0.1 | UI | |||
Data Input Total Jitter | TJ | 0.28 | UI | |||
Receiver | ||||||
Single Ended Output Voltage Tolerance | -0.3 | 4 | V | |||
Rx Output Diff Voltage | Vo | 300 | 850 | mV | ||
Rx Output Rise and Fall Time | Tr/Tf | 30 | ps | 20% to 80% | ||
Total Jitter | TJ | 0.7 | UI | |||
Deterministic Jitter | DJ | 0.42 | UI |
Control and Status I/O Timing Characteristics
Timing characteristics of control and status I/O are included in Pin Description table, which is also defined in SFF-8431.
Parameter | Symbol | Min. | Typ. | Max. | Unit | Note |
TX Disable Assert Time | t_off | 10 | μs | Time from rising edge of TX Disable to when the optical output falls below 10% of nominal | ||
TX Disable Negate Time | t_on | 1 | ms | Time from falling edge of TX Disable to when the modulated optical output rises above 90% of nominal | ||
Time to Initialize, including Reset of TX_Fault | t_init | 300 | ms | From power on or negation of TX Fault using TX Disable | ||
TX Fault Assert Time | t_fault | 100 | μs | Time from fault to TX fault on | ||
TX Disable to Reset | t_reset | 10 | μs | Time TX Disable must be held high to reset TX fault | ||
LOS Assert Time | t_loss_on | 100 | μs | Time from LoS state to RX LOS assert | ||
LOS Deassert Time | t_loss_off | 100 | μs | Time from non-LOS state to RX LOS deassert | ||
Rate-Select Change Time | t_ratesel | 10 | μs | Time from rising or falling edge of Rate Select input until receiver bandwidth is in conformance with appropriate specification | ||
Serial lD Clock Rate | t_serial_clock | 100 | kHz |
Digital Diagnostic Functions
The following digital diagnostic characteristics are defined over the Recommended Operating Environment unless otherwise specified. It is compliant to SFF8472 Rev10.2 with internal calibration mode. For external calibration mode please contact our sales stuff.
Parameter | Symbol | Min | Typ. | Max | Unit | Note |
Temperature Monitor Absolute Error | DMI_Temp | -3 | 3 | °C | Over operating temp | |
Laser Power Monitor Absolute Error | DMI_TX | -3 | 3 | dB | ||
RX Power Monitor Absolute Error | DMI_RX | -3 | 3 | dB | -7dBm to -20dBm range | |
Supply Voltage Monitor Absolute Error | DMI_VCC | -0.08 | 0.08 | V | Full operating range | |
Bias Current Monitor | DMI_Ibias | -10% | 10% | mA |


10 Gb/s 1310nm SFP+ 40 km Transceiver

SFPP-ATLP-31-20 SFP+ Plug-in, 10Gbps, 20km, TX=1310/RX wide, on two single mode fibers, LC/PC Blue

SFPP-ATLP-31-10 SFP+ Plug-in, 10Gbps, 10km, TX=1310/RX wide, on two single mode fibers, LC/PC Blue

SFPP-ATLP-31-02 10Gb/s 1310nm SFP+ 2 km Transceiver

SFPP-ATLP-51-40 10 Gb/s 1550 nm SFP+ 40 km Transceiver

SFPP-ATLP-51-100 10 Gb/s 1550 nm SFP+ 100 km Transceiver

SFPP-ATLP-51-80 10 Gb/s 1550 nm SFP+ 80 km Transceiver

10 Gb/s 850nm Multi-mode SFP+ Transceiver 400m

SFPP-ATLP-85-03 10 Gb/s 850nm Multi-Mode SFP+ Transceiver

SFPP-LP-T99R-80 10 Gb/s Tunable DWDM SFP+ 80 km Transceiver

SFPP-ATLP-DXX-80 10 Gb/s DWDM SFP+ 80 km Transceiver

SFPP-ATLP-DXX-40 SFP+ Plug-in, 10Gbps, 40km, TX=ITU Ch xx (17 to 61) /RX wide, on two single mode fibers, LC/PC Blue

SFPP-ATLP-CXX-80 SFP+ Plug-in, 10 Gbps, 80 km, TX = CWDM Ch xx (1470 nm to 1610 nm)/RX wide, on two single-mode fibers, LC/PC Blue.

SFPP-AT-LP-XXXX-60D 10 Gb/s BIDI SFP+ 60 km Transceiver

SFPP-ATLP-CXX-40 SFP+ Plug-in, 10Gbps, 40km, TX=CWDM Ch xx (1270 nm to 1610 nm) /RX wide, on two single mode fibers, LC/PC Blue

SFPP-ATLP-CXX-10 SFP+ Plug-in, 10 Gbps, 10 km, TX=CWDM Ch xx (1270 nm to 1610 nm)/RX wide, on two single-mode fibers, LC/PC Blue

SFP+ BIDI 10 Gb/s 1490/1550 nm 80 km Transceiver

SFPP-AT-LP-XXXX-40 SFP+ Plug-in, 10Gbps, 40km, TX=1270/RX=1330 , on one single mode fibers, LC/PC Blue

SFPP-LP-XXXX-10 SFP+ Plug-in, 10Gbps, 10km, TX=1270/RX=1330 , on one single mode fibers, LC/PC Blue

XFP 10 Gb/s BIDI Single-Mode 80 km Transceiver DDM

XFP 10 Gb/s BIDI Single-Mode 40 km Transceiver DDM

XFP 10 Gb/s BIDI Single-Mode 20 km Transceiver DDM

XFP 10 Gb/s BIDI Single-Mode 10 km Transceiver DDM

XFP-AT-LP-31-20 10 Gb/s 20 km XFP Transceiver

XFP-AT-LP-31-10 10 Gb/s 10 km XFP Transceiver

XFP-AT-LP-51-40 10 Gb/s 40 km XFP Optical Transceiver

XFP-AT-LP-51-80 10 Gb/s 80 km XFP Optical Transceiver

XFP-ATLP-XXXX-60 10 Gb/s BIDI XFP 60 km Transceiver

SFPP-ATLP-61-80 SFP+ Plug-in, 10Gbps, 80km, TX=1610/RX wide, on two single mode fibers, LC/PC Blue

SFPP-AT-CO-03 10GBASE-T SFP+ Copper RJ45 30m Transceiver

X2 10Gb/s 850nm Multi-mode Transceiver 300m

SFPP-16-LP-85-01 16 Gb/s 850 nm SFP+ 100 m Transceiver

SFPP-A8LP-85-015 8.5 Gb/s 850 nm Multi-Mode SFP+ Transceiver

SFPP-A6-LP-31-02 6.25 Gb/s Single-Mode SFP+ Transceiver

SFPP-A6-LP-85-03 6.25 Gb/s 850 nm Multi-Mode SFP+ Transceiver
Get in touch with our experts
Feedback