AON1100E Optical Receiver

AON1100E Series Optical Receiver is part of ACT’s Deep Fiber solution, which has been designed to deliver high-quality CATV and other advanced services in FTTB (fiber to the building) and FTTH (fiber to the home) application. This cost-effective compact mini receiver helps operators expand the bandwidth of their existing HFC network while minimizing capital investment. The AON1100E compact node has 1.2GHz bandwidth, adjustable EQ and ATT and optical input LED for convenient management and is suitable for MDU, FTTB or FTTC applications with high output up to 110 dBμV. The AON1100C deep fiber node is equipment with Automatic Gain Control circuit to maintain constant output power with optical input from ‑10 dBm to 0 dBm. Combined with ACT’s converged headend AH1000 optical platform, AON1100E series deep fiber optical node is an ideal product to provide MSOs with an economical, flexible HFC access solution. AON1100E node provides the split or tap output options with convenience in advanced network management system.

·        Utilizes advanced optical AGC technique, optical AGC control range: -10 dBm to 0 dBm

·        1.2GHz bandwidth with single optical signal input

·         RF amplifier part adopts the high-performance low power consumption GaAs chip, maximum output level up to 110 dBμV

·         EQ and ATT both use the adjustable control circuit, operation more convenient

·         Compact housing with two RF outputs

·         Split or Tap output options


Technique Parameters

Item

Unit

Technical Parameters

Optical Index

Optical Input Range

dBm

-12 to +2

AGC Setting Range

dBm

-10 to 0

Optical Return Loss

dB

>45

Operating Wavelength

nm

1100 to 1600

Fiber Connector


FC/APC, SC/APC, Specified by User

Fiber Type


SM

Link Index

CNR

dB

≥51

CTB

dB

≥65

CSO

dB

≥60

RF Index

Operating Bandwidth

MHz

47 to 1218

Output Level

dB

±0.75

Standard Output level

dBμV

≥106(Splitter)



≥110(Tap)

No. of Output Port


2 (FZ-210 or FP-214)

Return Loss

dB

≥16

Input Impedance

Ω

75

General Index

Anti-Thunder Voltage(10/700uV)

KV

5

Power Supply

Output

VDC

12VDC/1A


Input

VAC

100 to 240VAC

Operating Temp

°C

-40 to 60

Storage Temp

°C

-50 to 70

Operating Relative Humidity

%

Max 95%

Power Consumption

W

≤8

Dimension

mm

165(L)x 100(W) x 50(H)

 


image.png
image.png

Series Recommendation