ABA1000 Battery Management Station is a battery management system used to maintain, reactivate and test battery cells up to 12V. This system includes a battery charger, a battery discharger, a battery activator and system monitor.
• Charger, discharger, and activator functionality which can be used either separately or comprehensively
• Compatible with 2 V, 6 V, and 12 V battery cells
• Charges/discharges single and multi-cell batteries
• Constant current discharging with current, time and voltage setting
• Charging/discharging automatic stop with test time, capacity setting and over current protection
• Alarm when high temperature, opposing connection, battery wire disconnect, under or over voltage, over current conditions
• Data management software
• Easy-to-read LCD display
• Built-in safeguards to protect batteries during testing
• Highly accurate test results
• Compact design to save space
• Three stage charging: Constant current, Fixed Voltage, Reduced current – floating
ABA1000 Battery Management System
Item | 12 V ( 2V, 6V optional ) | |
Charge Current per Cell Voltage | Up to 15 A +/-0.01A | |
Discharge Current per Cell Voltage | Up to 50 A +/-0.01A | |
Charge and Discharge Voltage | 9.0V to 16 V | |
Temperature Censor | -10℃~55℃ +/- 0.001℃ | |
Impulse Cycle | 15s | |
Display | 800 × 480 pixel color LCD with touch screen | |
Power Requirements2 | 220 V±10% AC / 50 Hz | |
Operation Temperature | 0 to 50 °C | |
Operation Humidity | 5 % to 90 % RH (non-condensing) | |
Communication Port | RS232 or USB | |
Dimensions (L × W × H) | 42.5 mm × 20 mm × 30 mm | |
Weight | 15 kg |
1 Varies depending on battery capacity
2 Desired input voltage to be specified by customer